Dermot Asked :Can you point me at technical drawings - specifically the dimensions - of the Flova Str8 Exposed Thermostatic Bar Shower Valve - STTBV. (They appear to be on the web page but they are too small for me to see). I believe that this is the make of mixer bar we have and after 9 years of continuous use twice a day, it looks like we have a problem with the actual thermostatic valve. (We don't have the original receipts so I can't be sure that it is a Flova but it looks very much like one). If I had the dimensions, I could confirm that it is the Flova and then decide whether to try to replace the cartridge inside or get a new unit that will fit the existing inlet taps and riser bar. Many thanks, Dermot Flaherty
The required dimensions for replacing the bar shower valve is the inlet centres and inlet/outlet connections. The inlet centres of this valve is 150mm and inlet/outlet connections are G1/2 inch. For large view of dimensional drawing, refer this image url - https://assets-large.qssupplies.co.uk/QS-V27148_2_lg.jpg
We will soon verify the details and add your rating appropriately.